Search
Catalog Number: LTV-100
Derived from HEK 293 cell line
Selected for firm attachment to culture plates
Faster growth rates and greater lentiviral yields
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-206
Significantly reduced homology compared to other 3rd generation expression systems for added safety
Vectors provided individually to allow optimization of vector ratio
Contains three packaging plasmids (Rev, gag-pol, and VSVG) for use with your own third generation lentiviral transfer vector
…
Catalog Number: VPK-211
Cloning capacity = 9.4 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-214
Cloning capacity = 7.4 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-217
Cloning capacity = 7.3 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-216
Cloning capacity = 7.5 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-215
Cloning capacity = 7.8 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-213
Cloning capacity = 7.7 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-212
Cloning capacity = 7.9 kb
Frequently Asked Questions about this product
General FAQs about Viral Gene Delivery
Catalog Number: VPK-214-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-211-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-213-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-212-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-215-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-216-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: VPK-217-PAN
Significantly reduced homology compared to other 3rd generation expression systems for added safety, without loss of titer
Vectors provided individually to allow optimization of vector ratio
Complete Expression System contains packaging plasmids and expression vector
Cloning capacity of expression…
Catalog Number: STA-380, STA-380-5
For detection and quantitation of 5'-methyl-2'-deoxycytidine (5MedCyd)
Suitable for use with DNA samples such as cell or tissue genomic DNA
Detection sensitivity of 150 nM 5MedCyd
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-369
Suitable for use with human plasma or serum samples
Copper oxidized LDL (oxLDL) Standard included
Detection sensitivity limit of <50 ng/mL for MDA-LDL
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-378
Measures creatinine levels in urine samples
Detection sensitivity limit of 300 μg/dl
Creatinine standard included
Frequently Asked Questions about this product
Catalog Number: STA-390, STA-384
Suitable for use with serum, plasma, lysate, or tissue samples
Cholesterol standard included
Available with colorimetric or fluorometric detection
Frequently Asked Questions about this product
Catalog Number: STA-391
Allows you to separate and independently test HDL and LDL/VLDL fractions
Suitable for use with serum or plasma
Cholesterol standard included
Frequently Asked Questions about this product
Catalog Number: STA-375
Detection sensitivity limit of 0.5 µM of uric acid or 1 mU/mL uricase
Measures uric acid concentrations in biological samples such as serum, plasma, and urine without any need for pretreatment
Catalog Number: STA-394
Measures HDL cholesterol levels present in plasma or serum samples
Provides sufficient reagents which includes blanks, cholesterol standards, and unknown samples enough to perform 96 assays
Frequently Asked Questions about this product
Catalog Number: STA-382, MET-5180
Detects as low as 0.78 mg/dL urea (colorimetric) or .098 mg/dL urea (fluorometric).
Measures urea levels within urine, serum, plasma, cell lysates, or tissue homogenates
Provides sufficient reagents to perform up to 200 assays, including blanks, urea standards and unknown samples