Search
Catalog Number: AKR-110
Quickly solubilize and renature GST inclusion bodies
No lengthy dialysis or dilution steps
No pH variation or redox pair involved
Frequently Asked Questions about this product
Catalog Number: AKR-104 , AKR-103
Superior blocking compared to dry milk or serum
Enhances low level phosphoprotein signal without increasing background
Preserves phosphoprotein antigens during Western blot procedures
Easy-to-use premixed dry blend
Catalog Number: AKR-171, AKR-172
Simple and fast tool to isolate nuclear extract from the cytoplasmic fraction of mammalian cells
Extraction in less than 2 hours
Each prep can accommodate up to 5 x 106cells
Catalog Number: AKR-190, AKR-191
Buffer is able to extract cytoplasmic, membrane, and nuclear proteins
Available with or without Protease Inhibitor Cocktail
Suitable for downstream assays such as reporter assays, protein assays, immunoassays and protein purification
Catalog Number: MET-5016
Detects soluble collagen in cell and tissue lysates
Detection sensitivity of approximately 15 µg/ml collagen
Collagen standard curve included
Catalog Number: AKR-5182, AKR-5183, AKR-5184
Quick, simple and cost-effective method for immobilizing DNA and Oligonucleotides.
For use with Cell Biolabs' DNA High-Binding Plate (Part No. 232404).
Catalog Number: STA-680, STA-681
Suitable for use with serum, plasma, lysates, urine, cell culture supernatants, and food samples
Detection sensitivity limit of approximately 6.25 µM glucose (colorimetric) or 1.56 µM (fluorometric)
Glucose standard included
Catalog Number: STA-682
Colorimetric detection of total carbohydrates in serum, plasma, lysates, urine, cell culture supernatants or food samples
Detection sensitivity limit of approximately 0.0625 mM glucose
Glucose standard included
Catalog Number: MET-5001
Suitable for use with milk based food products or biological samples
Detection sensitivity limit of approximately 10µM lactose
Lactose standard included
Catalog Number: MET-5012, MET-5013
Detects L-lactate in plasma, serum, urine, saliva, and lysate samples
Detection sensitivity of approximately 1.5 µM L-lactate
Lactate standard curve included
Catalog Number: MET-5022, MET-5023
Suitable for use with serum, plasma, urine, lysates, and cell culture supernatants
Detection sensitivity of 3.75µM (colorimetric) or 0.12 µM (fluorometric)
Glycogen standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5025, MET-5026
Suitable for use with food samples
Detection sensitivity of 0.625 µg/ml
Starch standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5029
Suitable for use with serum, plasma, biological samples, and lysates
Detection sensitivity of 1µM (fluorometric) or 3 µM (colorimetric)
Pyruvate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5082, MET-5083
Detection sensitivity limit of approximately 31 µM (colorimetric) or 2 µM (fluorometric)
Suitable for use with serum, plasma, lysates, urine, cell lysates, and tissue homogenates
Beta-HB standard included
Catalog Number: MET-5119, MET-5120
Detect malate concentrations as low as 6.25 µM
Quantify in a standard colorimetric or fluorometric plate reader
Suitable for food and beverage samples, serum, plasma, urine, cell lysates and culture supernatants
Malate standard provided
Catalog Number: MET-5159
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 4 µM Pyrophosphate
Pyrophosphate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5160
Detection sensitivity limit of approximately 1.6 µM Adenosine Monophosphate
Suitable for use with lysates, serum, plasma, urine and culture supernatants
Adenosine Monophosphate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5162
Detection sensitivity limit of approximately 3.1 µM Phosphoenolpyruvate
Suitable for use with lysates, serum, plasma, urine and culture supernatants
Phosphoenolpyruvate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5156, MET-5157
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 3.25 µM Sialic Acid
Sialic Acid standard included
Catalog Number: MET-5163
Detection sensitivity limit of approximately 1.56 µM Adenosine triphosphate (ATP)
Suitable for use with lysates, serum, plasma, urine and culture supernatants
ATP standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5164
Detection sensitivity limit of approximately 3.1 µM Adenosine diphosphate (ADP)
Suitable for use with lysates, serum, plasma, urine and culture supernatants
ADP standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5167
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 3.1 µM 2-Phosphoglycerate (2-PG)
2-PG standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: AKR-5153
Detection sensitivity limit of 15.6 ng/ml LTA (Lipoteichoic Acid)
LTA (Lipoteichoic Acid) standard included
Suitable for use with serum, plasma, cell or tissue samples
Catalog Number: VPK-5170
Measures the RSV fusion protein as low as 156 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant RSV Fusion Protein Standard included