Search
Catalog Number: VPK-156
Measures the MuLV core protein (p30) as low as 300 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant MuLV p30 Standard included
Video: Color Development in an ELISA
Catalog Number: VPK-150-5, VPK-150
Measures the core antigen of Hepatitis B virus
Sensitive to as low as 1 ng/mL
Recombinant HBVcAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-151
Measures the core antigen of Hepatitis C virus
Sensitive to as low as 1 ng/mL
Recombinant HCVcAg standard included
Video: Color Development in an ELISA
Catalog Number: STA-357
For detection and quantitation of benzo(a)pyrene diol epoxide (BPDE) DNA adducts
BPDE-DNA standard included
Suitable for use with DNA samples such as cell or tissue genomic DNA
Video: Color Development in an ELISA
Catalog Number: VPK-5003, VPK-5003-5
Measures the Hepatitis B “e” antigen (HBeAg) in purified virus or unpurified viral supernatant
Detection limit of approximately 150 pg/ml
HBeAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-5004, VPK-5004-5
Measures the Hepatitis B surface antigen (HBsAg) in purified virus or unpurified viral supernatant
Detection limit of approximately 1 ng/ml
HBsAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-5145, VPK-5145-5
Measures the nucleocapsid (N) protein of SARS-CoV-2
Detect concentrations as low as 1.25 ng/mL of the nucleocapsid protein
Recombinant SARS-CoV-2 Nucleocapsid protein standard included
Catalog Number: AKR-5153
Detection sensitivity limit of 15.6 ng/ml LTA (Lipoteichoic Acid)
LTA (Lipoteichoic Acid) standard included
Suitable for use with serum, plasma, cell or tissue samples
Catalog Number: VPK-5155, VPK-5155-5
Measures the spike protein (S1 subunit) of SARS-CoV-2
Detects concentrations as low as 31.3ng/ml of the spike protein S1
Recombinant SARS-CoV-2 spike protein S1 standard included
Catalog Number: VPK-5161
Measures the Zika (strain MR 766) NS1 protein
Detects concentrations as low as 20pg/ml of the NS1 protein
Recombinant Zika (strain MR 766) NS1 protein standard included
Catalog Number: VPK-5169
Measures the adenovirus hexon protein as low as 156 pg/mL
Quantitation is performed on a standard microplate reader
Adenovirus Hexon Standard included
Catalog Number: VPK-5170
Measures the RSV fusion protein as low as 156 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant RSV Fusion Protein Standard included
Catalog Number: BCT-5173
Detection sensitivity limit of 1.2x10^4 CFU equivalents/ml E. coli O157
Heat Killed E.coli O157 standard included
Suitable for use with Food, Fecal or Environmental Samples
Catalog Number: VPK-5171
Measures the RSV nucleoprotein as low as 313 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant RSV Nucleoprotein Standard included
Catalog Number: VPK-5174
Measures the Influenza A Nucleoprotein as low as 625 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant Influenza A Nucleoprotein Standard included
Catalog Number: VPK-5172
Measures the human cytomegalovirus glycoprotein B (HCMV gB) protein as low as 625 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant HCMV gB Protein Standard included
Catalog Number: VPK-5175
Measures the Influenza B Nucleoprotein protein as low as 313 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant Influenza B Nucleoprotein Standard included
Catalog Number: BCT-5176
Detection sensitivity limit of 625 pg/mL Listeria monocytogenes p60
Recombinant Listeria monocytogenes p60 standard included
Suitable for use with Food, Fecal or Environmental Samples
Catalog Number: VPK-5178
Measures the herpes simplex virus glycoprotein D (gD) (HSV gD) protein as low as 313 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant HSV-2 gD Standard included
Catalog Number: VPK-5189
Functionally titers Influenza A infectivity.
Specific anti-Influenza A Nucleoprotein antibody included.
Catalog Number: VPK-5190
Functionally titers Influenza B infectivity.
Specific anti-Influenza B Nucleoprotein antibody included.
Catalog Number: VPK-5191
Functionally titers virus infectivity.
All assays are for research use only; they are not to be used for any clinical, in vitro or in vivo human or veterinary diagnostic purposes.
Catalog Number: STA-620, STA-621
Simple assays that quantitatively measure the alcohol concentration (primary alcohols only, including ethanol) in various samples using a 96-well microtiter plate format
Each kit provides sufficient reagents to perform up to 100 assays, including blanks, standards and unknown samples
Frequently…
Catalog Number: STA-674, MET-5080
Detection sensitivity limit of 6.25 µM (colorimetric format) or 0.3 µM (fluorometric format)
Suitable for use with lysates, cell culture supernatants, serum, plasma, and urine
Glutamate standard included
Catalog Number: MET-5097
Detects m6A levels as low as 80 ng/mL
Compatible with serum, plasma, urine, and RNA extracted from cells or tissues
N6-methyladenosine standard included