Catalog Number: STA-680, STA-681
Suitable for use with serum, plasma, lysates, urine, cell culture supernatants, and food samples
Detection sensitivity limit of approximately 6.25 µM glucose (colorimetric) or 1.56 µM (fluorometric)
Glucose standard included
Catalog Number: STA-682
Colorimetric detection of total carbohydrates in serum, plasma, lysates, urine, cell culture supernatants or food samples
Detection sensitivity limit of approximately 0.0625 mM glucose
Glucose standard included
Catalog Number: MET-5001
Suitable for use with milk based food products or biological samples
Detection sensitivity limit of approximately 10µM lactose
Lactose standard included
Catalog Number: MET-5012, MET-5013
Detects L-lactate in plasma, serum, urine, saliva, and lysate samples
Detection sensitivity of approximately 1.5 µM L-lactate
Lactate standard curve included
Catalog Number: MET-5022, MET-5023
Suitable for use with serum, plasma, urine, lysates, and cell culture supernatants
Detection sensitivity of 3.75µM (colorimetric) or 0.12 µM (fluorometric)
Glycogen standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5025, MET-5026
Suitable for use with food samples
Detection sensitivity of 0.625 µg/ml
Starch standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5029
Suitable for use with serum, plasma, biological samples, and lysates
Detection sensitivity of 1µM (fluorometric) or 3 µM (colorimetric)
Pyruvate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5082, MET-5083
Detection sensitivity limit of approximately 31 µM (colorimetric) or 2 µM (fluorometric)
Suitable for use with serum, plasma, lysates, urine, cell lysates, and tissue homogenates
Beta-HB standard included
Catalog Number: MET-5119, MET-5120
Detect malate concentrations as low as 6.25 µM
Quantify in a standard colorimetric or fluorometric plate reader
Suitable for food and beverage samples, serum, plasma, urine, cell lysates and culture supernatants
Malate standard provided
Catalog Number: MET-5159
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 4 µM Pyrophosphate
Pyrophosphate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5160
Detection sensitivity limit of approximately 1.6 µM Adenosine Monophosphate
Suitable for use with lysates, serum, plasma, urine and culture supernatants
Adenosine Monophosphate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5162
Detection sensitivity limit of approximately 3.1 µM Phosphoenolpyruvate
Suitable for use with lysates, serum, plasma, urine and culture supernatants
Phosphoenolpyruvate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5156, MET-5157
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 3.25 µM Sialic Acid
Sialic Acid standard included
Catalog Number: MET-5163
Detection sensitivity limit of approximately 1.56 µM Adenosine triphosphate (ATP)
Suitable for use with lysates, serum, plasma, urine and culture supernatants
ATP standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5164
Detection sensitivity limit of approximately 3.1 µM Adenosine diphosphate (ADP)
Suitable for use with lysates, serum, plasma, urine and culture supernatants
ADP standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5167
Suitable for use with serum, plasma, lysates, urine and cell culture supernatants
Detection sensitivity limit of approximately 3.1 µM 2-Phosphoglycerate (2-PG)
2-PG standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5056
Measures only free branched chain amino acids; does not detect peptides or proteins
Detection sensitivity limit of 15.6 µM
Suitable for use with lysates, serum, plasma, urine, and food samples
L-Leucine standard included
Catalog Number: MET-5123, MET-5124
Measure ALT activity from serum, plasma, cell or tissue lysates
Colorimetric and fluorometric plate-based detection formats
ALT positive control included
Catalog Number: MET-5014, MET-5030
Detects NAD+, NADH, or total NAD+/NADH
Compatible with cell or tissue lysates
NAD+ standard included
Catalog Number: MET-5018, MET-5031
Detects NADP+, NADPH, or total NADP+/NADPH
Compatible with cell or tissue lysates
NADP+ standard included
Catalog Number: MET-5138
Detect zinc concentrations as low as ~0.4µM
Suitable for serum, plasma, urine, cerebrospinal fluid, and cell or tissue lysates
Zinc standard included
Catalog Number: MET-5158
Detection sensitivity limit of approximately 1.5 µM Methionine
Suitable for use with lysates, serum, plasma, urine and culture supernatants
Methionine standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.