Search
Catalog Number: CBA-070, CBA-071, CBA-070-5, CBA-071-5
Full quantitation of cell adhesion with no manual cell counting
Fluorometric or colorimetric detection
Plates precoated with a uniform substrate layer of a single ECM protein in each row: Collagen I, Collagen IV, Fibrinogen, Fibronectin, and Laminin
Frequently Asked Questions about this product
Catalog Number: CBA-210
Quantify interactions between cells and the endothelium
Fully quantitative with no manual cell counting
Highly sensitive results on a fluorescence plate reader
Catalog Number: CBA-050, CBA-051
Full quantitation of cell adhesion with no manual cell counting
Fluorometric or colorimetric detection
Plates precoated with uniform substrate layer of Fibronectin
Frequently Asked Questions about this product
Catalog Number: STA-337, STA-337-5
Quantify 8-isoprostane in about 3 hours
Suitable for use with urine, plasma, serum, or cell lysates
8-iso-PGF2alpha included as positive control
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Video: Color Development in an ELISA
Catalog Number: STA-330, STA-330-5
Quick screening tool for oxidative stress
User friendly protocol uses smaller reaction volumes in a 96-well format
Does not require glass tubes or marbles
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-832, STA-832-5
Detect as little as 6 pmol/mL of malondialdehyde
More specific for MDA than traditional TBARS assay
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Video: Color Development in an ELISA
Catalog Number: STA-838, STA-838-5, STA-838-T
Measure HNE protein adduct levels in a variety of samples including cell and tissue lysates, serum, plasma, and purified proteins
HNE-BSA standard included
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Video: Color Development in an ELISA
Catalog Number: STA-369
Suitable for use with human plasma or serum samples
Copper oxidized LDL (oxLDL) Standard included
Detection sensitivity limit of <50 ng/mL for MDA-LDL
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-388
Suitable for use with human plasma or serum samples
Copper oxidized LDL (oxLDL) Standard included
Detection sensitivity limit of 150 ng/mL for CML-LDL
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-389
Suitable for use with human plasma or serum samples
Copper oxidized LDL (oxLDL) Standard included
Detection sensitivity limit of 150 ng/mL for HNE-LDL
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: VPK-156
Measures the MuLV core protein (p30) as low as 300 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant MuLV p30 Standard included
Video: Color Development in an ELISA
Catalog Number: VPK-150-5, VPK-150
Measures the core antigen of Hepatitis B virus
Sensitive to as low as 1 ng/mL
Recombinant HBVcAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-151
Measures the core antigen of Hepatitis C virus
Sensitive to as low as 1 ng/mL
Recombinant HCVcAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-5003, VPK-5003-5
Measures the Hepatitis B “e” antigen (HBeAg) in purified virus or unpurified viral supernatant
Detection limit of approximately 150 pg/ml
HBeAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-5004, VPK-5004-5
Measures the Hepatitis B surface antigen (HBsAg) in purified virus or unpurified viral supernatant
Detection limit of approximately 1 ng/ml
HBsAg standard included
Video: Color Development in an ELISA
Catalog Number: VPK-5145, VPK-5145-5
Measures the nucleocapsid (N) protein of SARS-CoV-2
Detect concentrations as low as 1.25 ng/mL of the nucleocapsid protein
Recombinant SARS-CoV-2 Nucleocapsid protein standard included
Catalog Number: VPK-5155, VPK-5155-5
Measures the spike protein (S1 subunit) of SARS-CoV-2
Detects concentrations as low as 31.3ng/ml of the spike protein S1
Recombinant SARS-CoV-2 spike protein S1 standard included
Catalog Number: VPK-5161
Measures the Zika (strain MR 766) NS1 protein
Detects concentrations as low as 20pg/ml of the NS1 protein
Recombinant Zika (strain MR 766) NS1 protein standard included
Catalog Number: VPK-5169
Measures the adenovirus hexon protein as low as 156 pg/mL
Quantitation is performed on a standard microplate reader
Adenovirus Hexon Standard included
Catalog Number: VPK-5170
Measures the RSV fusion protein as low as 156 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant RSV Fusion Protein Standard included
Catalog Number: VPK-5171
Measures the RSV nucleoprotein as low as 313 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant RSV Nucleoprotein Standard included
Catalog Number: VPK-5174
Measures the Influenza A Nucleoprotein as low as 625 pg/mL
Quantitation is performed on a standard microplate reader
Recombinant Influenza A Nucleoprotein Standard included