Catalog Number: MET-5008
Detection sensitivity limit of 30 nM chenodeoxycholic acid
Suitable for use with plasma, serum, feces, and cell and tissue lysates
Chenodeoxycholic acid standard included
Video: Color Development in an ELISA
Catalog Number: MET-5010
Measures total bilirubin in plasma, serum, or cell and tissue lysates
Detection sensitivity of 0.5mg/dL bilirubin
Bilirubin standard curve included
Catalog Number: MET-5011
Isolates lipid droplets from cells or tissues
Uses a simple gradient centrifugation protocol
No ultracentrifugation required
Catalog Number: MET-5012, MET-5013
Detects L-lactate in plasma, serum, urine, saliva, and lysate samples
Detection sensitivity of approximately 1.5 µM L-lactate
Lactate standard curve included
Catalog Number: MET-5019
Detects total phosphatidic acid content (PA and LPA) in cell lysate samples
Detection sensitivity of approximately 5 µM phosphatidic acid
Phosphatidic Acid standard curve included
Catalog Number: MET-5022, MET-5023
Suitable for use with serum, plasma, urine, lysates, and cell culture supernatants
Detection sensitivity of 3.75µM (colorimetric) or 0.12 µM (fluorometric)
Glycogen standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5025, MET-5026
Suitable for use with food samples
Detection sensitivity of 0.625 µg/ml
Starch standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5029
Suitable for use with serum, plasma, biological samples, and lysates
Detection sensitivity of 1µM (fluorometric) or 3 µM (colorimetric)
Pyruvate standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5014, MET-5030
Detects NAD+, NADH, or total NAD+/NADH
Compatible with cell or tissue lysates
NAD+ standard included
Catalog Number: MET-5018, MET-5031
Detects NADP+, NADPH, or total NADP+/NADPH
Compatible with cell or tissue lysates
NADP+ standard included
Catalog Number: MET-5028
Suitable for use with cell lysates
Detection sensitivity of 4 µM DAG
DAG standard include
NOTE: Each sample replicate requires 2 assays for proper data calculation.
Catalog Number: MET-5027
Suitable for use with plasma, serum, urine, and lysates
Detection sensitivity of 37.5 µM homocitrulline or citrulline
Homocitrulline and citrulline standards included
Catalog Number: MET-5054, MET-5055
Measure only free L-amino acids (except glycine); does not detect peptides or proteins
Detection sensitivity limit of 62.5 µM (colorimetric) or 6.25 µM (fluorometric)
Suitable for use with lysates, serum, plasma, urine, and food samples
L-Alanine standard included
Catalog Number: MET-5056
Measures only free branched chain amino acids; does not detect peptides or proteins
Detection sensitivity limit of 15.6 µM
Suitable for use with lysates, serum, plasma, urine, and food samples
L-Leucine standard included
Catalog Number: MET-5068, MET-5068-5
Detection sensitivity limit of 24 pg/mL
Suitable for use with plasma, serum, and lysates
Folic acid standard included
Video: Color Development in an ELISA
Catalog Number: MET-5071
Detection sensitivity limit of 15.6 µM taurine
Suitable for use with plasma, serum, urine, and cell and tissue lysates
Taurine standard included
Catalog Number: MET-5070
Detection sensitivity limit of 1.56 µM glycine
Suitable for use with lysates, serum, plasma, saliva and urine
Glycine standard included
Measures only free glycine; will not detect glycine in peptides or proteins
Catalog Number: MET-5073
Detection sensitivity limit of 15.6 µM free tyrosine
Suitable for use with lysates, serum, plasma, saliva and urine
Tyrosine standard included
Catalog Number: MET-5082, MET-5083
Detection sensitivity limit of approximately 31 µM (colorimetric) or 2 µM (fluorometric)
Suitable for use with serum, plasma, lysates, urine, cell lysates, and tissue homogenates
Beta-HB standard included
Catalog Number: MET-5086, MET-5181
Detects as low as 12.5 µM ammonia (colorimetric) or 6.25 µM ammonia (fluorometric).
Measures ammonia levels within urine, cell lysates, or tissue homogenates
Provides sufficient reagents to perform up to 100 assays (colorimetric) or 200 assays (fluorometric), including blanks, ammonia standards…
Catalog Number: MET-5085
Simple fluorometric plate-based assay
Suitable for plasma or serum, tissue homogenates, or cell suspensions
Measures phospholipid levels as low as 200 nM
Catalog Number: MET-5090
Detects adenosine levels as low as 1.56 µM
Compatible with cell or tissue lysates, serum, plasma, or urine
Adenosine standard included
Catalog Number: MET-5092
Detects inosine levels as low as 300 nM
Compatible with cell or tissue lysates, serum, plasma, or urine
Inosine standard included
Catalog Number: MET-5097
Detects m6A levels as low as 80 ng/mL
Compatible with serum, plasma, urine, and RNA extracted from cells or tissues
N6-methyladenosine standard included
Catalog Number: MET-5093
Detection sensitivity limit of 7.8 µM in a standard colorimetric plate reader
Suitable for use with lysates, serum, plasma, urine, cell lysates and culture supernatants
L-Alanine standard included
NOTE: Each sample replicate requires 2 assays for proper data calculation.