Catalog Number: STA-337, STA-337-5
Quantify 8-isoprostane in about 3 hours
Suitable for use with urine, plasma, serum, or cell lysates
8-iso-PGF2alpha included as positive control
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Video: Color Development in an ELISA
Catalog Number: STA-312
Measures total glutathione (oxidized and reduced)
Sensitive detection as low as 8 nM
Suitable for use with serum, plasma, saliva, urine, tissue extracts, and mammalian or plant cell lysates
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-360
Measures total antioxidant capacity based on reduction of copper(II) to copper(I)
Suitable for use with plasma, serum, urine, cell lysates, tissue homogenates and food extracts
Works with a wide variety of antioxidants
Frequently Asked Questions about this product
General FAQs about Oxidative…
Catalog Number: STA-341, STA-339
Quantify catalase activity in about 60 minutes
Suitable for use with plasma, serum, cell lysates or tissue homogenates
Catalase standard included for absolute quantitation
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-346, STA-346-5
Obtain results in less than 2 hours
Suitable for use with plasma, cell fractions, tissue lysates, solid and aqueous nutrition samples
Antioxidant standard included
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-345, STA-345-5
Obtain results in less than 2 hours
Suitable for use with plasma, cell fractions, tissue lysates, solid and aqueous nutrition samples
Antioxidant standard included
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-340
Measure superoxide dismutase activity using a standard microplate reader
Suitable for use with plasma, serum, cells or tissues
Superoxide dismutase standard included for absolute quantitation
Frequently Asked Questions about this product
General FAQs about Oxidative Stress
Catalog Number: STA-349
Determine the efficacy of an exogenous antioxidant compound within a cellular environment
Each kit provides sufficient reagents to perform up to 192 assays, including standard curve and unknown samples
Catalog Number: STA-812
Detection sensitivity limit of approximately 0.6 mU/mL
Sufficient reagents to perform up to 100 assays, including standard curve and unknown samples
Catalog Number: STA-860
Specifically differentiates ascorbic acid content from other antioxidant compounds
Detects ascorbic acid concentrations as low as 1.56 µM
Suitable for use with serum, plasma, urine, saliva, tissue homogenates, cell extracts, and purified food or drug extracts
NOTE: Each sample replicate requires…
Catalog Number: STA-859
Quick, 10 minute protocol
Measures antioxidant potential in samples through the reduction of ferric iron (Fe3+) to ferrous iron (Fe2+)
Detection sensitivity limit of approximately 4 µM Fe2+ iron equivalents
Suitable for use with serum, plasma, lysates, biological fluids, and purified food or drug…
Catalog Number: XAN-5040
Measures total antioxidant capacity based on conversion of ABTS radical to ABTSW
Suitable for use with plasma, serum, urine, cell lysates, tissue homogenates and food extracts
Works with a wide variety of antioxidants
General FAQs about Oxidative Stress
Catalog Number: XAN-5084
Suitable for use with samples containing a hydrogen sulfide donor, such as enzymes, cells or tissues
Sodium sulfide standard included
Catalog Number: XAN-5077
Detection sensitivity of 2 µg/mL of Quercetin equivalents
Suitable for use with serum, plasma, tissue extracts and food extracts
Quercetin standard included
Catalog Number: XAN-5126
Detect Chitosan concentrations as low as 6.25 µg/mL
Suitable for use with serum, urine, or shell extracts
Chitosan standard provided
Catalog Number: STA-380, STA-380-5
For detection and quantitation of 5'-methyl-2'-deoxycytidine (5MedCyd)
Suitable for use with DNA samples such as cell or tissue genomic DNA
Detection sensitivity of 150 nM 5MedCyd
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-369
Suitable for use with human plasma or serum samples
Copper oxidized LDL (oxLDL) Standard included
Detection sensitivity limit of <50 ng/mL for MDA-LDL
Frequently Asked Questions about this product
Video: Color Development in an ELISA
Catalog Number: STA-378
Measures creatinine levels in urine samples
Detection sensitivity limit of 300 μg/dl
Creatinine standard included
Frequently Asked Questions about this product
Catalog Number: STA-390, STA-384
Suitable for use with serum, plasma, lysate, or tissue samples
Cholesterol standard included
Available with colorimetric or fluorometric detection
Frequently Asked Questions about this product
Catalog Number: STA-391
Allows you to separate and independently test HDL and LDL/VLDL fractions
Suitable for use with serum or plasma
Cholesterol standard included
Frequently Asked Questions about this product
Catalog Number: STA-375
Detection sensitivity limit of 0.5 µM of uric acid or 1 mU/mL uricase
Measures uric acid concentrations in biological samples such as serum, plasma, and urine without any need for pretreatment
Catalog Number: STA-394
Measures HDL cholesterol levels present in plasma or serum samples
Provides sufficient reagents which includes blanks, cholesterol standards, and unknown samples enough to perform 96 assays
Frequently Asked Questions about this product
Catalog Number: STA-382, MET-5180
Detects as low as 0.78 mg/dL urea (colorimetric) or .098 mg/dL urea (fluorometric).
Measures urea levels within urine, serum, plasma, cell lysates, or tissue homogenates
Provides sufficient reagents to perform up to 200 assays, including blanks, urea standards and unknown samples
Catalog Number: STA-398, STA-399
Quantitatively measures the amount of glycerol in plasma or serum in a 96-well microtiter plate format
Kits provide sufficient reagents to perform up to 100 assays, including blanks, glycerol standards and unknown samples
Catalog Number: STA-396, STA-397
Measure triglyceride concentration in serum, plasma, and lysates by a coupled enzymatic reaction system
Simple assay that quantitatively measures the amount of triglyceride in a 96-well microtiter plate format
Kits include triglyceride standards and free glycerol controls